Section 8 − Maintenance & Troubleshooting; Routine Maintenance - Miller Big Blue 300 P Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Big Blue 300 P:
Table of Contents

Advertisement

SECTION 8 − MAINTENANCE & TROUBLESHOOTING

8-1. Routine Maintenance

n = Check
* To be done by Factory Authorized Service Agent
Every
8
Hours
n Coolant Level
Every
50
Hours
~ Weld Terminals
Every
100
Hours
~ Battery Terminals
Every
250
Hours
l Unreadable Labels
Every
500
Hours
nl Weld Cables
Every
1000
Hours
n Radiator Fluid Level
n~ Slip Rings*
nl Brushes*
Every
2000
Hours
~ Injectors*
Z = Change
~ = Clean
n Fuel Level
n Air Cleaner Hoses
1/2 in.
(13 mm)
n Fan Belt Tension
Z Fuel Filter
OR
~ Inside Unit
!
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
Recycle engine
for important start-up, service, and storage
fluids.
information. Service engine more often if
used in severe conditions.
l = Replace
n Oil Level
~ Oil, Fuel Spills
n Air Cleaner Element
Z Oil Z Oil Filter
n~ Spark Arrestor
Z Inline Fuel Filter
n Radiator Thermostat
SLUDGE
n Valve Clearance*
~ Drain Sludge
Reference
Section 5-8,
8-8
Section 8-3
Engine
Manual,
Section 8-4
Section 5-8,
FUEL
8-10, 8-8
and Engine
Manual
OM-236 948 Page 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents