5-4. Activating The Dry Charge Battery (If Applicable)

2
1
Tools Needed:

5-5. Connecting The Battery

Tools Needed:
1/2 in
3
4
+
!
Connect (−) Cable Last.
+
!
Remove battery from unit.
1
2
3
Fill each cell with electrolyte to
bottom of well (maximum).
!
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
!
5
6
5
Charge battery. Disconnect charg-
ing cables and install battery.
.
5 A
6
30 A
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Vent Caps
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
Well
Do not overfill battery cells.
Battery Charger
Read and follow all instruc-
tions supplied with battery
charger.
5 Amperes For 30 Minutes
Charge Time
30 Amperes For 12 Minutes
Charge Time
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
drybatt 12008−01 − S-0886
Ref 225 543 / 153 654-C
OM-225 590 Page 23