4 Replacement Procedures
8. Removing the following screw, remove the GND cable and washer from the LCD unit.
M1.4x2.0S
?
CAUTION: GND cable is removed from LCD unit only when LCD unit must be replaced.
PORTEGE M300 Maintenance Manual (960-504)
S-THIN FLAT BIND screw
Caulking side
Figure 4-43 Removing the GND cable
4.27 LCD unit/ FL inverter
? 1
LCD unit
GND cable
Washer
M1.4x2.0S S-THIN FLAT BIND
4-61