FRONT PANEL CONTROLS

4.1
1.
WIRE SPEED CONTROL
Use this control to adjust wire feed speed. When
wire speed is increased, welding amperage
increases. When wire feed speed decreases,
welding amperage decreases.
2.
VOLTAGE SWITCH
Use this control to turn the wire feed unit on and to
adjust welding voltage. Thicker material will require
higher voltage settings.
Do not switch under load.
The same switch is to be used to turn the power ON and OFF.

5 MAINTENANCE AND TROUBLESHOOTING

DISCONNECT THE POWER SOURCE
FROM POWER SUPPLY BEFORE PERFORM-
ING ANY MAINTENANCE WORK.
Periodically, remove the side panels and blow out
the machine with dry compressed air to remove
dirt and dust.
Increase the frequency of cleaning when operating
in dirty or dusty conditions.

4 OPERATION

3.
DATA PLATE
M 130
M 170

BACK PANEL CONTROLS

4.2
1.
2.
.

TORCH MAINTENANCE

5.1
As required, clean the interior of the gas nozzle to
prevent buildup of spatter.
To change the contact tip:
1. Slide off the gas nozzle.
2. Unscrew the contact tip.
3. Fit the new contact tip.
4. Replace the gas nozzle.
To change the gas diffuser:
1. Slide off the gas nozzle.
2. Unscrew the contact tip.
3. Unscrew the gas diffuser and replace.
4. Fit the contact tip.
5. Fit the gas nozzle.