Poe Allocation Using Lldp Information; Hp Procurve 3500Yl Pwr Switches; Maximum Poe Power - HP ProCurve 2520 Planning And Implementation Manual

Procurve power over ethernet (poe/poe+)
Hide thumbs Also See for ProCurve 2520:
Table of Contents

Advertisement

PoE Allocation Using LLDP Information

You can have the port automatically configure certain PoE link partner devices
if the devices supports advertising of its PoE needs. By enabling PoE LLDP
detection, available information about the power usage of the PD will be used
by the switch to configure the power allocation. The default configuration is
for PoE information to be ignored if detected through LLDP.
For more information, see the Management and Configuration Guide on the
ProCurve Web site at www.hp.com/go/procurve/manuals.

HP ProCurve 3500yl PWR Switches

Maximum PoE Power

The Switch 3500yl-24G-PWR provisions (allocates power to) ports 1-24 with
398 watts of power for PoE applications compatible with the IEEE 802.3af
standard and some pre-standard devices. The Switch 3500yl-48G-PWR
provisions ports 1-48 with 398 watts. This reduces the average per port wattage
by half as compared to the Switch 3500yl-24G-PWR.
An external power supply, the 620 RPS/EPS (J8696A) can be connected to
either of the 3500yl switches to provide redundant or extra PoE power. The
620 RPS/EPS can be connected to up to two switches and provide 388 watts
of 50V power to each switch.
Table 2-7.
PoE Devices
PoE for Switch
398 watts available to
3500yl-24G-PWR
PoE for Switch
398 watts available to
3500yl-48G-PWR
Maximum Power Allocations for the 3500yl Switches
Internal Only
Internal and External
398 watts available to ports 1-24
ports 1-24.
(provided by the internal source).
388 watts available as backup in
case of failure, provided by the
786 watts available to ports 1-48
ports 1-48.
(provided by both the internal and
external sources).
The internal power supply
has failed, and the external
source provides 388 watts to
external source.
The internal power supply
has failed, and the external
source provides 388 watts to
always be allocated to both
port groups (ports 1-24 and
Operating Rules
Provisioning Power for PoE
External Only
ports 1-24.
ports 1-48. Note that a
minimum of 22 watts will
ports 25-48).
2-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents