CALIBRATION ADJUSTMENT

A 1/16 inch flat blade screwdriver with a 2 inch shaft is required to adjust the thermostat.
Maintain the oven temperature at 350°F degrees.
Without turning the thermostat dial, pull it off the shaft of the thermostat.
Locate the screw at the base of the thermostat shaft; this is the thermostat calibration screw.
Insert a small flat blade screwdriver down the thermostat shaft until it contacts the screw.
Grasp the thermostat shaft so it does not move while turning the calibration screw.
Use caution when making adjustments to the thermostat, a 1/8 turn of the calibration screw
will adjust the oven temperature about 5 to 7 degrees.
To raise the oven temperature, turn the calibration screw Counter-Clock-Wise.
To lower the oven temperature, turn the calibration screw Clock-Wise.
Reinstall the oven knob and recheck the oven temperature
.
12