Replacement Of Main Parts; U Case; Front Panel Assembly - Sony PMW-EX30 Service Manual

Solid-state memory recorder
Hide thumbs Also See for PMW-EX30:
Table of Contents

Advertisement

n
Before starting the procedure, pull out the power cable con-
nected to this unit.

2-1. U Case

1. Remove the fi ve screws, then remove the U case in the
direction of the arrow.
2. To install, reverse the removal procedure.

2-2. Front Panel Assembly

1. Remove the U case. (Refer to Section 2-1.)
2. Disconnect the harness and fl exible fl at cable from the
connectors (CN1160 and CN1201) on the AVP-11
board.
3. Disconnect the harness from the connector (CN200) on
the DPR-297 board.
4. Remove the fi ve screws, then remove the front panel
assembly.
5. To install, reverse the removal procedure.
PMW-EX30
Section 2

Replacement of Main Parts

U case
B3 x 6
CN1201
CN1160
Flexible flat cable
Harness
B3 x 6
Front panel assembly
B3 x 6
B3 x 6
DPR-297 board
CN200
AVP-11 board
Harness
B3 x 6
2-1