Category
Subcategory
M Black
Iris
RM Diag
System
DIP SW
Pnl Test
Version
Preset
ALLReset
Item
Setting
Item
Rel, Abs
Scal
1/1, 1/2, 1/4
Ctrl
Rel, Abs
Scal
1/1, 1/2, 1/4
Min
Cls, 22 to 1.0
Max
Cls, 22 to 1.0 (1.4)
Mode
RM, CAM
COM
OK, Sens, Open
Obj
...., CHU, CCU, CNU
S1-1
On, Off
S1-2
On, Off
S1-3
On, Off
S1-4
On, Off
S1-5
On, Off
S1-6
On, Off
S1-7
On, Off
S1-8
On, Off
Location and Function of Parts and Controls
(An Underlined item under 'Setting' indicates the factory setting.)
Contents
Selects the adjustment mode of the M BLACK control knob.
Rel: Relative mode, Abs: Absolute mode
Selects the adjustment range of the M BLACK control knobs in Relative mode. The
adjustment range is set as a fraction of the entire variable range.
Selects the adjustment mode of the IRIS control.
Rel: Relative mode, Abs: Absolute mode
Selects the adjustment range of the IRIS control in relative mode. The adjustment
range is set as a function of the entire variable range.
Sets the minimum adjustment value (f) in Absolute mode.
Sets the maximum adjustment value (f) in Absolute mode.
Selects the variable range mode in Absolute mode.
RM: The iris is adjusted within the min. and max. values set on this menu.
CAM: The iris is automatically adjusted according to the iris file data of the camera.
(effective only with a camera equipped with an automatic detection facility)
Shows the communication status of the command port (CAMERA connector).
OK: Normal
Sens: Communication is not possible.
Open: No connector connected.
Shoes the connected device.
....: None
CHU: Camera head
CCU: Camera control unit
CNU: Camera network unit
Shows DIP switch S1-1 status (S1=CPU-266 board S1)
Shows DIP switch S1-2 status (S1=CPU-266 board S1)
Shows DIP switch S1-3 status (S1=CPU-266 board S1)
Shows DIP switch S1-4 status (S1=CPU-266 board S1)
Shows DIP switch S1-5 status (S1=CPU-266 board S1)
Shows DIP switch S1-6 status (S1=CPU-266 board S1)
Shows DIP switch S1-7 status (S1=CPU-266 board S1)
Shows DIP switch S1-8 status (S1=CPU-266 board S1)
Executes the panel test.
To set the unit in Test mode, push the CANCEL/ENTER switch towards ENTER with
this subcategory selected ('Pnl Test' displayed).
In Test mode, the test of switches, LEDs and volumes can be made.
To release Test mode, push the RM Configuration switch in the
holding the CANCEL/ENTER switch at ENTER.
Displays the version information.
To display the information, push the CANCEL/ENTER switch towards ENTER with
this subcategory selected ('Version' displayed).
The ROM version of this unit is displayed (The display can be scrolled with the
menu select knob).
To cancel the version display, push the CANCEL/ENTER switch towards CANCEL.
Returns (resets) all the settings made by the RM Configuration menu to the factory
settings.
Operating procedure:
1. Push the RM Configuration switch in the
selected ('All Reset' displayed) while holding the CANCEL/ENTER switch at
ENTER. 'All Reset' flashes on the display.
2. Push the CANCEL/ENTER switch towards ENTER .'OK' flashes on the display.
3. Push again the CANCEL/ENTER switch towards ENTER.
4. Reset is executed.
5. When reset is completed, 'Complete' appears for several seconds. By pushing the
CANCEL/ENTER switch towards CANCEL in step 3, the reset operation can be
canceled.
*1 Which value may be selected depends on the camera being used.
direction while
direction with this subcategory