3
RECORD SET
5
Set "PICTURE QUALITY".
[Settings] (
indicates the default setting)
Setting
BASIC (BA)
15 kB
NORMAL (NO)
22 kB
ENHANCED(EN)
30 kB
FINE (FI)
42 kB
SUPER FINE (SF) 50 kB
The file size is intended as a general guideline and
actual sizes will depend on the recorded video.
The maximum number of alarm recordings as determined
by the alarm settings is displayed in parentheses.
Maximum number of
alarm recordings
6
Set "AUDIO RECORDING".
When set to "ON", the letter "A (indicating that audio will be
recorded)" is displayed in front of recording rate, and the
maximum number of alarm recordings is displayed in
parenthesis.
[Settings] (
indicates the default setting)
Setting
OFF
Audio recording is not carried out.
ON
Audio recording is carried out.
[Setting conditions]
Audio recording is possible when "REC RATE" is set to
1.00 FPS or greater.
English
Description
Description
69
7
SET "ALARM INTERLEAVE"
[Settings] (
indicates the default setting)
Setting
Recording is switched between camera video including
SW
an alarm and video from all connected cameras.
Video is recorded only from cameras with an alarm
ONLY
occurring.
* Recording pattern for "SW" and "ONLY"
SW
Alarm
Alarm
01
02
03
02
04
02
05
04
Alternate recording of multiple items of alarm video
ONLY
Alarm
Alarm is cancelled
01
02
03
02
02
02
02
02
Recording until the alarm is cancelled
8
Set "REC RATE" and "DURATION"
The maximum number of recording alarms (shown in
parentheses) changes in accordance with the new
settings.
(Default setting for recording rate: 15.00 FPS)
(Default setting for duration: 20 SEC)
Maximum number of
alarm recording
[Settings]
Setting
REC RATE 30.00 to 0.03 FPS Sets the recording rate.
5 SEC, 10 SEC,
20 SEC, 40 SEC,
1 MIN, 2 MIN,
DURATION
3 MIN, 4 MIN,
5 MIN, 10 MIN,
15 MIN, CC*
* Operates while an alarm is being triggered. (5 sec. minimum)
Description
06
02
07
04
08
02
04
Description
Sets the recording time per
alarm.

Hide quick links: