3.4 CABLE REQUIREMENTS

EQUIPMENT
DIGITAL KEYSET
ADD-ON MODULE
SINGLE LINE STATION
DOOR PHONE
*This the maximum distance a door phone can be from the DPIM. The DPIM can be up to 900 cable feet from the
KSU. The total distance must not exceed 1230 feet.
3.5 RINGS AND TONES

3.5.1 RING CYCLES

The OfficeServ 7030 provides the trunk line rings, station rings, door rings, and alarm rings. The ON/OFF cycle of
each ring is shown in the table below (it is different according to the country, and can be modified by MMC pro-
gramming).
3.5.1a SYSTEM RING CYCLES
RING
TRUNK LINE RING
STATION RING
DOOR RING
ALARM RING
Note: The ON/OFF cycle can be adjusted by changing the values of the system database.
CABLE
AWG
1 PR. TWISTED
1 PR. TWISTED
1 PR. TWISTED
2 PR. TWISTED
ON/OFF CYCLE
1000/2000 ms
400/200/400/3000 ms
400/200/400/200/400/2000 ms
400/200/400/200/400/200/400/1000 ms
3.2
MAX FEET
24
1300
24
1300
24
3000
24
330*
MAX METERS
400
400
1 KM
100