Sharp AR-203E Service Manual page 86

Digital multifunctional system/digital copier
Hide thumbs Also See for AR-203E:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
24
15
Scanner mode counter clear
(AR-203E/M200/M201)
25
01
Main motor operation check
(Cooling fan motor rotation
check)
10
Polygon motor ON
26
02
SPF/RSPF setup
03
Second cassette setup
[Function]
When [OK]/[ENTER]/[START] key is pressed, the scanner mode counter value is cleared to 0,
and "000,000" is displayed on the LCD/display.
[Operation]
AR-M200/M201
1) Initial display
24-15 S-MODE CLR.
CLEARED
[Function]
When [OK]/[ENTER]/[START] key is pressed, the main motor (and the duplex motor in the case
of a duplex model) is operated for 30sec.
To reduce toner consumption, if the developing unit is installed, the developing bias, the main
charger, and the grid are also outputted.
In this case, laser discharge is required when stopping the motor, the polygon motor is also
operated at the same time. Check for installation of the developing unit. If it is not installed, the
high voltage above is not outputted and only the motor is rotated.
To check the developing bias, install the developing unit.
After completion of 30sec operation, the machine goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
1) Initial display
25-01 MAIN MOTOR CHK
EXECUTING...
[Function]
When [OK]/[ENTER]/[START] key is pressed, the Bios is called to rotate the polygon motor for
30sec.
After completion of 30sec operation, the operation is turned off with the Bios and the machine
goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
1) Initial display
25-10 LSU CHK
EXECUTING...
[Function]
When this simulation is executed, the current set SPF/RSPF is displayed. Enter the code num-
ber corresponding to the desired SPF/RSPF and press [OK]/[ENTER]/[START] key to save the
setting.
Code number
0
SPF NO
1
SPF YES
2
RSPF YES
For the AR-203E/5420, the code number cannot be set to 2.
For the AR-M200/M201, the code number cannot be set to 1.
[Operation]
AR-M200/M201
1) The current set value is
displayed.
26-02 SPF/RSPF
1:SPF
ON
(0- 2)
2) [Numeric] key or [
26-02 SPF/RSPF
0:SPF
OFF (0- 2)
[Function]
When this simulation is executed, the current set second cassette is displayed. Enter the code
number corresponding to the desired second cassette and press [OK]/[ENTER]/[START] key to
save the setting.
Code number
0
Second cassette NO
1
Second cassette YES
For the AR-203E/5420/M200/M201, the code number cannot be set to 1.
[Operation]
The operation is similar to simulation 26-02.
AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 13
Details of function/operation
AR-203E
The operation is similar to simulation 20-01.
000,000
SPF/RSPF
Display item
SPF OFF
SPF ON
RSPF ON
2) [Numeric] key or [
26-02 SPF/RSPF
2:RSPF ON
(0- 2)
3) [OK]/[ENTER]/[START]
] key
key
26-02 SPF/RSPF
2:RSPF ON
(0- 2)
Second cassette
Display item
AR-203E/5420
] key
1) Press [ ] [ ] key to
change the code number.
2) Press [START] key to fix
the code number.
OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m201Ar-m200Ar-5420

Table of Contents