6) Attach the Scanner motor metal plate cushion at 1 position on
the attachment plate of the motor on the rear side of the main
unit.
Note: The hole on the top of the motor unit should be covered
with the mylar.
Align the edge of the metal plate and the edge of the cushion
(the yellow line in the diagram below).
Press and attach the cushion aligning it to the metal plate so
that there will be no gap between them.
7) Attach the Scanner upper surface cushion on the top and the
rear side at the rear side of the main unit.
Align the cushion with the side of the raised part (the yellow
line in the diagram below).
Do not cover this hole.
20mm - 25mm
Align the edge of the cushion with
the edge of the metal plate.
AR-203E/5420/M200/M201 UNPACKING AND INSTALLATION 5 - 11
Bend the part which is sticking out to the rear side of the scan-
ner and attach to the surface.
Press the cushion at the steps shown in the diagram so that
there will be no gap.
Press the cushion to make sure all the holes are covered.
8) Bend the edge of the Scanner motor lower mylar and stick
together.
Stick together.
9) Attach the Scanner motor lower mylar at 1 position under the
motor attachment plate on the rear side of the main unit.
Note: The mylar should cover the hole under the motor unit.
Attach matching the hole (the yellow mark in the diagram) and
along with the side edge (the yellow arrow in the diagram).
Disconnect the motor harness from the connector and take off
the snap band from the hole.
Press the mylar with a sharp-pointed stick or something so
that it is stuck correctly.
Stick together.