Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the Dynamic Battery Test
to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the number of minutes, and the [r] stores
the data and moves to the next segment of this location.
The "Listen-In" feature cannot be enabled for UL Listed systems.
The "Dynamic Battery Test" feature cannot exceed four (4) hours.
The dial delay shall be set to -0-. Must be disabled by zone type in Loc 110-169.
The combined Dial Delay and Entry Delay (loc 24) must not exceed 1 minute for SIA CP-01 requirements.
Segment 1 -
Dynamic Battery Test duration in minutes 0-255 minutes ..................................... (0 = no test)
Segment 2 -
AC Fail report delay in minutes 0-255 minutes. .................................................... (0 = no delay)
Segment 3 -
Power Up Delay in seconds 0-60 seconds ........................................................... (0 = no power up delay)
Segment 4 -
Siren Time in minutes 1-254 minutes.
Segment 5 -
Telephone Line Cut delay in seconds 0-255 seconds........................................... (0 = no TLM)
Segment 6 -
Cross Zone time in minutes 0-255 ........................................................................ (0 = no cross zoning)
Segment 7 -
Chime time in 50 mS (1/20th second) increments from 0-12 seconds .................. (0 = follows zone 255 latched)
Segment 8 -
Dial delay in seconds 15-255 seconds.................................................................. (0 = no abort delay)
Segment 9 -
Fire Alarm Verification time in seconds 120-255 seconds..................................... (0 = no fire alarm verification)
NOTE: The fire alarm verification feature is not approved for residential use in California
Segment 10 -
Listen-In time in seconds 0-255 ............................................................................ (0 = no Listen-In time)
Segment 11 -
Zone Activity Monitor feature timed in days 0 – 255 ............................................. (0 = disabled)
Segments 12-14 Reserved.
41
Segment 1:
1 =
On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To Program Code" are 6
digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-DIGIT CODE
BEFORE EXITING PROGRAMMING.
2 =
On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming call for download)
functions.
3 =
Enable Auto Cancel / Abort (Refer to Glossary beginning on page 35)
4 =
Enable Walk-Test Mode (Refer to Glossary beginning on page 35)
5 =
On enables Auto Force-Arming with keyfob or keyswitch.
L
42
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code option is enabled
in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments (digits)
will be ignored. With the NX-4V2 disarmed, the "Go To Program Code" can be used to enter the Program Mode.
43
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user ID is 255.
(This code may not be changed in the Run Mode.)
Segment 1:
1 = Reserved.
2 = On enables "Go To Program Code" as an arm only code.
3 = On enables "Go To Program Code" as an arm only after closing.
4 = On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = On enables "Go To Program Code" as an arm/disarm code.
6 = On enables "Go To Program Code" to bypass zones.
7 = On enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2: Reserved
L
44
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is enabled in Location 41,
THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location 41, the last 2 digits will be ignored.
45
NX-4V2 Control
SYSTEM TIMERS
NOTES FOR UL INSTALLATIONS
SPECIAL FEATURES
GO TO PROGRAM CODE
GO TO PROGRAM CODE & AUTHORIZATION
DURESS CODE
RESERVED
WWW.DIYALARMFORUM.COM
14........... numerical
1............. feature select
6............. numerical
2............. feature select
6............. numerical