Xvii. Appendix 2 - GE NetworX NX-4V2 Installation And Startup

Networkx series control panel
Hide thumbs Also See for NetworX NX-4V2:
Table of Contents

Advertisement

XVII.
APPENDIX 2
REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-4V2 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists of an Event
Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come from the chart below and
be programmed in the zone type event code.
Programmed Event Code
0 .......................................................HA ..............................................................Holdup Alarm
1 .......................................................FA...............................................................Fire Alarm
2 .......................................................PA ..............................................................Panic alarm
3 .......................................................BA ..............................................................Burglary Alarm
4 .......................................................BA ..............................................................Burglary Alarm
5 .......................................................BA ..............................................................Burglary Alarm
6 .......................................................UA ..............................................................Untyped Alarm
7 .......................................................BA ..............................................................Burglary Alarm
8 .......................................................BA ..............................................................Burglary Alarm
9 .......................................................UA ..............................................................Untyped Alarm
10 ......................................................HA ..............................................................Holdup Alarm
11 ......................................................MA..............................................................Medical Alarm
12 ......................................................PA ..............................................................Panic alarm
13 ......................................................TA...............................................................Tamper Alarm
14 ......................................................RP ..............................................................Periodic Test
15 ......................................................GA ..............................................................Gas Alarm
16 ......................................................KA ..............................................................Heat Alarm
17 ......................................................WA .............................................................Water Alarm
18 ......................................................QA ..............................................................Emergency Alarm
19 ......................................................SA ..............................................................Sprinkler Alarm
20 ......................................................ZA...............................................................Freeze Alarm
21 ......................................................KH ..............................................................High Temp Alarm
22 ......................................................FA...............................................................Manual Fire Alarm
The NX-4V2 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a
Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be programmed in the
zone type event code.
Programmed Event Code
0 .......................................................122 .............................................................Silent Panic
1 .......................................................110 .............................................................Fire Alarm
2 .......................................................120 .............................................................Panic alarm
3 .......................................................130 .............................................................Burglary Alarm
4 .......................................................131 .............................................................Perimeter Alarm
5 .......................................................132 .............................................................Interior Alarm
6 .......................................................133 .............................................................24 Hour Burglary
7 .......................................................134 .............................................................Entry Alarm
8 .......................................................135 .............................................................Day/Night Alarm
9 .......................................................150 .............................................................Non Burglary 24 Hour
10 ......................................................121 .............................................................Duress Alarm
11 ......................................................100 .............................................................Medical Alarm
12 ......................................................123 .............................................................Audible Panic Alarm
13 ......................................................137 .............................................................Tamper Alarm
14 ......................................................602 .............................................................Periodic Test
15 ......................................................151 .............................................................Gas Detected
16 ......................................................158 .............................................................High Temp
17 ......................................................154 .............................................................Water Leakage
18 ......................................................140 .............................................................General Alarm
19 ......................................................140 .............................................................General Alarm
20 ......................................................159 .............................................................Low Temp
21 ......................................................158 .............................................................High Temp Alarm
22 ......................................................115 .............................................................Manual Fire Alarm
40
SIA Code
Contact ID Code
WWW.DIYALARMFORUM.COM
Description
Description
NX-4V2 Control