LOC
PG
L
19
14
DOWNLOAD ACCESS CODE
L
20
14
RINGS TO ANSWER DOWNLOAD
L
21
15
DOWNLOAD CONTROL
Segment 1
1 = Enables two call answering machine defeat
2 = Enables tone sniff answering machine defeat
3 = Requires callback before downloading
4 = Shutdown control panel
5 = Lock out local programming
6 = Lock out communicator programming
7 = Lock out download section
8 = Enables callback at autotest interval
L
22
15
CALLBACK PHONE NUMBER
L
23
15
FEATURE SELECTION
Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
Segment 3
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
Segment 4
1 = Late to Close / Early to Open
2 = Auto Arm in Stay Mode
3 = Disables door delays in Night mode
4-8 = Reserved
Segment 5 RESERVED
L
24
16
ENTRY / EXIT TIMERS
Segment 1 (Entry Time 1)
Segment 2 (Exit Time 1)
Segment 3 (Entry Time 2)
Segment 4 (Exit Time 2)
Segments 5 & 6
L
25
17
ZONES 1-8, ZONE TYPES
29-36
17
RESERVED
L 37
17
SIREN AND SYSTEM SUPERVISION
Segment 1
1 = Siren sounds for telephone line cut while armed.
2 = Siren sounds for telephone line cut while disarmed.
3 = Siren blast at arming.
4 = Siren blast at exit delay expiration.
5 = Siren blast at closing kissoff.
6 = Siren sounds during a cross-zone verification time.
7 = Siren sounds for a tamper.
8 = Siren blast one time for keyswitch arming, two times for disarming.
installations.)
Segment 2
1 = Convert siren driver to voltage out.
2 = Siren sounds for expander trouble (required for U.L.).
3 = Immediate Restore by zone.
4 = Dynamic battery test performed upon arming.
5 = Battery missing test performed every 12 seconds.
6 = Manual bell test performed during [
7 = Manual communicator test performed during [r]-[4]-[4] test function.
8 = Box tamper enabled.
NX-4V2 Control
DESCRIPTION
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
WWW.DIYALARMFORUM.COM
DEFAULT
8-4-8-0-0-0-0-0
8
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables automatic instant
8 = Enables Instant mode toggle
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
30
60
30
60
Reserved
3-5-6-6-6-6-6-6
r
]-[4]-[4] test function.
PROGRAM DATA
_ _ _ _ _ _ _ _
_
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _ _ _
(Note: Must be disabled for SIA CP-01
29