3.4.5.3 500-25 Network Card Indicators and Switches
•
D1 and D2 will, under normal operation, flash at 1Hz and 2Hz respectively. If
there is a problem during start-up, one or both LEDs will flash considerably
faster.
•
D13 should be on under normal operating conditions. The LED turns off when
data comes in from a remote link but the off duration is very short and not
visible. It is therefore only useful to show an error condition.
•
D20 is turned on just after power-up then turned off under TDM control shortly
afterwards. The LED is also on during a TDM reconfiguration process. The state
of the LED is duplicated on a remote 500-25 if connected directly.
Trilogy Communications Limited
Commander Installation Guide
LED
Legend
D8
+5V
D1
1
1
D2
2
|
D6
RESET
|
|
D3
NO E1 CLK
|
D9
TDM D
|
D10
1 DIS
|
D11
BUSY
|
D12
COM1
|
D13
E1 DIS
|
D14
2 DIS
13
D15
BUSY
D16
COM2
LED
Legend
D17
1
D18
2
Reset
D19
3
D20
4
1
|
D21
5
|
D22
6
|
D23
7
|
D24
8
8
DIP Switch Functions
Sw
Function
1
Cable Match
2
Cable Length
3
undefined
4
undefined
5
undefined
6
UART IN
7
UART OUT
8
ERR CORR
Issue 9.1
Activity
Function
On
+5V
1Hz
DSP 1 OK
2Hz
DSP 2 OK
Off
Reset
Off if net available
No E1 Clock
Off when started
TDM Disabled
Off when started
DSP Disabled (TDM)
Quick flash
TDM Busy
Quick flash
DSP Comms (TDM)
Off if data available
E1 Disabled
On when E1 down
NET DSP Disabled
On when buffers full
NET DSP Busy
Unused
NET DSP Comms
Activity
Function
1Hz
DSP 1 & 2 sync'd
On when full
IN Buffer full
On when full
OUT Buffer full
On during start then off
E1
command
On
Possible RX Data loss
On if clk missing
E1 Clock off
Normally toggles
Receiving H IP Data
Normally toggles
Transmitting H IP Data
Default
Note
OFF=
ON = Co-ax
CAT 5
ON =
OFF = "long"
norm
OFF
OFF
OFF
clk
&
event
off
Page 29 of 81
Need help?
Do you have a question about the Commander and is the answer not in the manual?