Upper Housing Unit Removal - Epson LX-300+II RTP Service Manual

9-pin serial impact dot matrix printer
Hide thumbs Also See for LX-300+II RTP:
Table of Contents

Advertisement

EPSON LX-300+II/300+II RTP/1170II

7.1.2 Upper Housing Unit Removal

1.
Remove the tractor unit.
2.
Set the release lever to the tractor feed.
3.
Remove 4 screws securing the upper housing to the lower housing.
4.
Detach the upper housing.
5.
Disconnect the lead wire of cover open switch assy from the relay connector, and
remove the Upper Housing.
When installing the upper housing, be sure to insert LEDs on the
C H E C K
P O I N T
panel board into the LED holes of the upper housing.
LX-300+II RTP
Upper Housing
LED
Panel Board Assembly
DISASSEMBLY AND ASSEMBLY
Upper Housing
C.B.P., Tite, 3x10 F/ZN
CPB (3x10)
Figure7-2. Upper Housing Removal (1)
Lead wire of Cover
Open Switch Assy
Relay connector
Figure7-3. Upper Housing Removal (2)
Revision D
Release lever