EPSON LX-300+II/300+II RTP/1170II
Table A-13. EEPROM Address Map (continued)
Address
Explanation
b0: Font function
b1: (reserved)
b2: Pause function
b3: (reserved)
3CH
Panel mask pattern 2
b4: (reserved)
b5: (reserved)
b6: (reserved)
b7: (reserved)
Copy mode
b0: copy mode
-----
b1: (reserved)
-----
b2: (reserved)
-----
b3: (reserved)
3DH
Energy save mode
b4: Energy save mode
-----
b5: (reserved)
-----
b6: (reserved)
-----
b7: (reserved)
Tear-off adjustment
-432 to +432 (-25.4 mm (-1inch) to 0 mm
3E,3FH
value
+25.4 mm (1inch), by 0.0588 mm (1/432 inch)
40H
Tear-off wait time
3 to 30 (by 0.1 sec.), 00H:3 sec.(same as default)
Manual insertion wait
3 to 30 (by 0.1 sec.), 00H:1.5 sec.(same as
41H
time
default)
42H-4FH (reserved)
Area 2
50H-51H (reserved)
52H-5AH
USB ID
5BH-63H
00H: Error is not recorded
30H: CR Error
32H: CG Error
64H
Fatal error (Latest)
33H: Head Low Volt Error
3AH: Head open Error
3BH: EEPROM Compare Error
65H
Fatal error (Record #1) (The same as the above)
66H
Fatal error (Record #2) (The same as the above)
67H
Fatal error (Record #3) (The same as the above)
Sub-number for
68H-6AH
00H to 09H
customization
6BH
(reserved)
6CH
Market CG
0:Standard version 1:NLSP version
Appendix
QPIT
Factory
Setting
Settings
Settings
00H
00H
0: Off
1: On
00H
00H
0: On
1: Off
0000H
0000H
00H
00H
(3 sec.)
(3 sec.)
00H
00H
(1.5 sec.)
(1.5 sec.)
All 00H
All 00H
00H
00H
All 00H
*a)
All 00H
*a)
00H
00H
00H
00H
00H
00H
00H
00H
000000H
000000H
(Standard)
(Standard)
00H
00H
00H
00H
EEPROM Address Map
Table A-13. EEPROM Address Map (continued)
Address
Explanation
6DH
IBM character table
0:Table2 1:Table1
6EH
(reserved)
6FH
(reserved)
70H
Vp adjustment value
Vp adjustment value
71H
(complement of 70H)
Bi-d adjustment value
72H
for high speed draft
-12 to +12 by 0.0353 mm(1/720 inch)
mode
Bi-d adjustment value
73H
-12 to +12 by 0.0353 mm(1/720 inch)
for draft mode
Bi-d adjustment value
74H
-12 to +12 by 0.0353 mm(1/720 inch)
for NLQ mode
75H-7BH (reserved)
RPE (TOF) position
7CH
adjustment for
-128 to +127 by 0.0588 mm (1/432 inch)
continuous
RPE (TOF) position
7DH
adjustment for
-128 to +127 by 0.0588 mm (1/432 inch)
continuous
RPE (TOF) position
7EH
adjustment for
-128 to +127 by 0.0588 mm (1/432 inch)
continuous
7FH
(reserved)
Revision D
QPIT
Setting
Settings
00H
00H
00H
Area 3
*a)
*a)
00H
00H
00H
All 00H
00H
00H
00H
00H
Factory
Settings
00H
00H
00H
*a)
*a)
*a)
*a)
*a)
00H
*a)
*a)
*a)
00H
116