EPSON LX-300+II/300+II RTP/1170II
Paper thickness lever:
The paper thickness lever must be set at the proper position as shown below.
Table 1-5. Paper Thickness Lever
LX-300+II
Paper thickness
Lever
(inch)
position
Min.
Max.
—1
—
—
0
(0.0024)
(0.0071)
up to 0.18
1
(0.0071)
(0.0102)
up to 0.26
2
(0.0102)
(0.0130)
up to 0.33
3
(0.0130)
(0.0154)
up to 0.39
4
(0.0154)
(0.0205)
up to 0.52
5
—
—
6
—
—
PRODUCT DESCRIPTION
LX-1170II
Paper thickness
Paper
Paper
(inch)
thickness
thickness
(mm)
Min.
Max.
—
—
—
over 0.06
over 0.06
(0.0024)
(0.0071)
up to 0.18
over 0.18
—
—
over 0.26
over 0.18
(0.0071)
(0.0102)
up to 0.26
over 0.33
—
—
over 0.39
over 0.26
(0.0102)
(0.0130)
up to 0.33
over 0.33
—
(0.0130)
(0.0154)
up to 0.39
over 0.39
—
(0.0154)
(0.0205)
up to 0.52
1.2.3 Electrical Specification
Rated voltage
Input voltage range
(mm)
Rated frequency range
Input frequency range
—
Rated current
Power consumption
—
Dielectric strength
—
1.2.4 Environmental Condition
Temperature:
Humidity:
Resistance to shock:
Resistance to vibration:
*1: without condensation
*2: during printing on reclaimed paper, multi part paper, envelop, label or
roll paper.
*3: without shipment container
SPECIFICATIONS
Table 1-6. Electrical Specification
120V version
AC 120 V
AC 99 to 132 V
50 to 60 Hz
49.5 to 60.5 Hz
0.6 A (max. 1.4 A)
Approx. 23 W (ISO/IEC 10561 Letter pattern)
Energy Star Compliant
AC 1000 Vrms. 1 min. or
AC 1500 Vrms. 1 min.
AC 1200 Vrms. 1 sec.
(between AC line and chassis)
(between AC line and chassis)
5 to 35
C (operating
)
°
*
1
15 to 25
C (operating
1,
2
)
°
*
*
-30 to 60
C (non-operating)
°
10 to 80% RH (operating
1
)
*
30 to 60% RH (operating
)
*
1,
*
2
0 to 85% RH (non-operating
*
1
1 G, within 1 ms (operating)
2 G, within 2 ms (non-operating
0.25 G, 10 to 55 Hz (operating)
0.50 G, 10 to 55 Hz (non-operating
Revision D
230V version
AC 220 to 240 V
AC 198 to 264 V
0.3 A (max. 0.7 A)
)
3
)
*
)
*
3
13