Model CLR2160
9. Unplug unit power cord from electrical outlet.
10. Reinstall back panel.
To connect to drain:
1. Attach the 5/8" ID drain connection on the back of the
unit to a 5/8" OD rigid tube, using a worm clamp.
2. Attach the other end of the rigid tube to your 5/8" ID
drain line with a worm clamp.
3. Insulate the drain line, if necessary, to prevent
condensation.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have
If a gravity drain connection is not possible and you have not
a model
not purchased the CLR2160 with factory-installed pump,
purchased a model with factory-installed pump, we strongly
we strongly recommend the use of the U-Line P60 drain
recommend the use of the EIMP60 drain pump. The EIMP60
EIMP60
pump. The U-Line P60 drain pump is available through
drain pump is available through your dealer. If a pump other
your dealer, or direct from U-Line with complete
than the EIMP60 is to be used, it must meet the following
installation instructions. If a pump other than the U-Line
specifications:
P60 drain pump is to be used, it must meet the following
specifications:
• It must be UL listed and have a UL listed, 120 VAC,
3-wire grounded power cord.
• It must have overall maximum outside dimensions of
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 15 gallons per
hour at 10 feet of lift.
• It must have a sealed sump which does not allow water
leakage in the case of a power outage, restricted drain
or pump failure.
• It must have a check valve in the discharge line to
prevent waste water return to the pump.
• It must have an overflow protection control which will
shut off power to the ice maker in the event of a pump
failure.
• It must have an operating temperature range of 50°F
to 110°F (10°C to 40°C).

U-CLR Drain Kit (Available for Purchase)

Tools Required:
• 1/4" Nut driver or flat 5/16" screwdriver
• Side cutter
• Copper tubing cutter
• 12" Level
• 9/16" Open end wrench
• 7/16" Open end wrench
• Pliers
Materials Required:
• (10' or more depending on water supply location) 1/4"
O.D. soft copper tubing
• **(10' or more depending on drain location) 5/8" I.D.
braid reinforced PVC drain tubing
42
Service Information
• **(3) 11/16" to 1-1/4" Clamp range worm drive hose
clamps
• **(1) Brass garden hose fitting (supplied with product)
• **(1) Nylon barbed coupling for 5/8" ID hose
• **(1) 5/8" to 7/8" adapter
** Depending on your model, your unit may have been
packaged with these items. If you need to order these items,
please contact U-Line and order Part # U-CLRDRAINKIT.
NOTE: These instructions are based on the U-Line
recommendations and common industry practice. You
must consult your local plumbing codes to ensure
compliance. U-Line requires the use of copper cold water
supply connection tubing. Plastic tubing should not be
water supply connection. Plastic tubing should not be used.
used.
EIMP60
1. Locate the desired cold water supply location. Attach a
1/4" copper line to this location and route the tubing
to the appliance. Leave approximately 8' of water line
to be coiled behind the appliance as shown (Figure 9).
This water line should be looped into 2 coils. This will
allow the line to flex when moving the appliance in
and out of the opening.
2. Locate the U-Line supplied garden hose fitting. Ensure
the end of the copper tubing has been cut straight and
is free of burrs. Slide the compression nut and ferrule
onto the copper tubing as shown (Figure 10). Push the
assembly completely into the garden hose fitting and
tighten using the two wrenches. Wait to connect this
assembly to the appliance until the drain connection is
ready.
Copper tubing is recommended for the cold
Figure 9
33
ULIN_S_165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E15im60gssE15im60gps

Table of Contents