12
Service Information

Blackout / Sabbath Mode

This mode allows for observation of holidays on
which lights cannot be activated. Hold the LIGHT
key for 10 seconds until the °F starts flashing.
When released, the unit will beep once and the
display and cabinet light will shut off. It will stay off
for 36 hours, at which time it will automatically turn
back on. If desired, you can manually cancel this
mode by touching the LIGHT key. Release and the
unit will automatically start normal operation.

Model Number Change

Model Selection:
1 Ensure board is not plugged in.
2 Hold down ON/OFF key and plug in unit.
3 Release ON/OFF key.
4 Press and release LIGHT key.
5 Use WARMER / COLDER to select the
model.
6 Press and release LIGHT key.
7 Wait for display to stop.
8 Unplug unit and wait 5 seconds.
9 Plug unit back in.

Service Menu

Enter the Service Menu by holding WARMER and
pressing LIGHT key three times. Select option 1 to
16 with the WARMER and COLDER keys. To enter
the option, press LIGHT key.
When entering Service Mode all other modes
are cancelled and the unit will stop operating.
When exiting the Service Mode, the unit will begin
to operate normally. However, the four minute
compressor off cycle still applies.
1 Light all LED segments
This will illuminate all the LED's on the board
to ensure they work properly.
2 Thermistor 1 status - Temperature, E1, or
E2
This will show the pure thermistor reading
with no offsets taken into account. When
placed in ice water, this thermistor should
read 32° F in this menu option.
3 Error Log
A list of the errors in the order they occured
will scroll once on the display. Repeat if
desired. Once viewed, perform Option 12 to
clear the errors from memory.
4 Defrost Information
Displays the number of defrosts that have
occured in the past 24 hours.
5 Compressor runtime based on last cycle
This will show the number of minutes the
compressor has run in the prior cycle (or
current cycle if the compressor was running
when Service Mode was entered).
6 Defrost length adjust min - 99 minutes
The length of the defrost can be adjusted
up to 99 minutes long (for every six hours).
The other defrost parameters will apply.
Lengthening a defrost may cause higher
than normal temperaturesin the refrigeration
section.
7 Light switch 1 status - 0 to 1
This will tell if the light should turn off with
the door switch or not. At the "0" reading the
light should be off with the door closed and
on with the door open. At the "1" reading the
light always stays on.
8 Display toggle status - 0 or 1
This will tell if the display should turn off with
the door switch or not. At the "0" reading the
light should be off with the door closed and
on with the door open. At the "1' reading the
light always stays on.
9 Restore factory defaults
This will restore the factory default setpoint,
defrost and offset values.
10 Adjust Thermistor 1 offset - 10 to +10°F
This allows calibration of the sensor to the
cabinet for abnormal operations. By adjusting
the number colder you can change the
average temperature to a colder value.
11 Data download
Along with the separate ESPY software you
can download the rolling data file.
12 Clear error log
Perform this operation after checking the
errors.
13 Clear download memory
Clears the rolling data file, if desired.
14 Model number displayed
Displays the two digit model number of the
specific unit
15 Adjust Thermister 1 differential
This number should not be adjusted.
16 Software number
This will show the software on the board.