4-6. Automatic Flap Control

The flap position can be selected from 5 positions.
F0
F1
F2
F3
F4
① The fl ap moves to the following position automatically when the indoor unit is stopped.
F0 (close): Types K1, T1, U1, Y1
F5: Models other than the above
② The fl ap closes once and moves to the set position when the operating mode is changed.
※ If the flap position cannot be adjusted because of a problem, only the swing operation can be
used. Check the fl ap and fl ap motor.
※ The swing operation can be set for the fl ap.
4

4-7. Filter Sign

① When accumulated operating time of the indoor unit reaches the set time, the fi lter sign appears on
the remote controller. Clean the fi lter.
Refer to "7-3. Detailed Setting Function: Simple setting items and Filter sign ON times for each model".
② After cleaning the fi lter, press the fi lter button on the remote controller once. The fi lter sign turns off.
Operating mode
Cooling/Dry
Fan
Heating
F5
Flap position
F1 F2 F3
F1 F2 F3 F4 F5
F1 F2 F3 F4 F5
4-8