AUI Device and Keypad Programming Fields
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
FIELD
TITLE and DATA ENTRIES
AUI Device 1 and 2 Enable
*189
(for Touch Screen Style Keypads)
0 = disabled
1 = partition 1
2 = partition 2
3 = common partition
NOTE: Use of AUI does not affect the number of
standard keypads supported.
Keypad 2 Device Address 17
*190
Entry 1 – Partition Assignment:
0 = keypad disabled
1 = partition 1
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E beeps and
chime beeps
Keypad 3 Device Address 18
*191
Keypad 4 Device Address 19
*192
Keypad 5 Device Address 20
*193
Keypad 6 Device Address 21
*194
Keypad 7 Device Address 22
*195
Keypad 8 Device Address 23
*196
Exit Time Display Interval
*197
0 = no display
1-5 = seconds between display refreshing
Display Partition Number
*198
0 = no; 1 = yes
ECP Device Fail Display
*199
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
EXPLANATION
The System supports up to two touch screen style keypads (e.g.,
Symphony Advanced User Interface, and 6270 Touch Screen Keypad).
Enter each AUI's home partition.
AUI Compatibility Note: To ensure proper AUI device operation,
use AUI devices with the following rev levels: 6270 series use
version 1.0.9 or higher; 8132/8142 (Symphony) series use version
1.1.175 or higher.
Touch Screen (AUI) device 1: Must set AUI device address to 1
Touch Screen (AUI) device 2: Must set AUI device address to 2
Keypad 2
Entry 1: enter the partition in which the keypad is located
2 = partition 2
Entry 2: Enter the desired sound option for this keypad.
3 = partition 3
NOTE: Address 16 is reserved for keypad 1, which is factory set to
partition 1 with all sounds enabled.
Keypad 3 See field *190 for entries and explanation.
Keypad 4 See field *190 for entries and explanation.
Keypad 5 See field *190 for entries and explanation.
Keypad 6 See field *190 for entries and explanation.
Keypad 7 See field *190 for entries and explanation.
Keypad 8 See field *190 for entries and explanation.
If enabled, keypads display the exit delay time remaining after arming
the system, with display updates at the interval selected (i.e. if the exit
delay is 30 seconds and "2" is selected in this field, the keypad display
refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than "1" may be necessary for some older keypads
to allow users time to enter key presses between display updates.
If selected, the partition number is displayed in the upper-left corner
of the display. This is useful when using the GOTO partition function.
Select "0" if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads (6148, 6150, 6160, 6164). ECP faults for keypads and/or
other peripheral ECP devices will display "1" plus the device address
(00-30) of device causing the fault (e.g., faults on device 07 display as
"107").
Select "1" if using 2-digit Fixed-Word Display keypads (e.g., certain
6128RF series keypads). If selected, ECP faults for keypads and/or
peripheral devices will display as "91" on 2-digit displays, and "191"
on 3-digit or Alpha keypads.
4-13