A/D Converter Calibration - Rabbit Core RCM3700 User Manual

C-programmable core module with ethernet, serial flash, and enhanced software
Hide thumbs Also See for Core RCM3700:
Table of Contents

Advertisement

B.1.5.4 A/D Converter Calibration
To get the best results from the A/D converter, it is necessary to calibrate each mode (sin-
gle-ended, differential, and current) for each of its gains. It is imperative that you calibrate
each of the A/D converter inputs in the same manner as they are to be used in the applica-
tion. For example, if you will be performing floating differential measurements or differ-
ential measurements using a common analog ground, then calibrate the A/D converter in
the corresponding manner. The calibration must be done with the attenuator reference
selection jumper in the desired position (see Figure B-5). If a calibration is performed and
the jumper is subsequently moved, the corresponding input(s) must be recalibrated. The
calibration table in software only holds calibration constants based on mode, channel, and
gain. Other factors affecting the calibration must be taken into account by calibrating
using the same mode and gain setup as in the intended use.
Sample programs are provided to illustrate how to read and calibrate the various A/D
inputs for the three operating modes.
Mode
Single-Ended, one channel
Single-Ended, all channels
Milliamp, one channel
Differential, analog ground
These sample programs are found in the Dynamic C
tory. See Section 3.2.3 for more information on these sample programs and how to use
them.
RabbitCore RCM3700 User's Manual
Read
AD_CALSE_CH.C
AD_RDSE_ALL.C
AD_CALSE_ALL.C
AD_RDMA_CH.C
AD_CALMA_CH.C
AD_RDDIFF_CH.C
AD_CALDIFF_CH.C
SAMPLES\RCM3700\ADC
Calibrate
subdirec-
102