Data to be stored
Faults
All faults stored in
diagnostic codes
Fault duration
The period the warning
light is ON is integrated in
minutes.
(Maximum stored period:
9999 minutes S 7 days)
Number of times
The number of times the
memory can
diagnostic codes and fault
be erased
durations
erased by a scan tool is in-
tegrated.
(Maximum number of
times to be stored: 250)

3. Diagnostic function

Fault diagnosis continues to be performed during the period
the ignition switch is ON except during cranking. If a fault
is detected, the SRS warning light is lit.
The microcomputer determines a diagnostic code on the basis
of the results of measurements by various measuring circuits
and stores it in "EEPROM".
The fault duration (the period the warning light has been ON)
is integrated in increments of a minute and stored in the EE-
PROM together with the diagnostic code. The stored data can
1 4 x 0 2 9
be read and erased by a scan tool. The number of times the
memory has been erased by a scan tool is stored in the "EE-
PROM" to provide reference information on the past service
history. The data can be read by a scan tool in the same
way as the fault durations.
NOTE
Description
Once a fault is detected, the SRS warning light continues
to light, even if normal operation of the system is restored,
until the diagnostic code is erased.

4. Automatic diagnostic code erasure function

The automatic diagnostic code erasure function operates
according to the indicated diagnostic code No. (Refer to
nostic code to be displayed returns to the normal condition,
if the malfunction reoccurs continuously at 5-second inter-
vals, the appropriate malfunction code can be erased. At
have
been
this time, if all other diagnostic codes have been erased,
the SRS warning light will switch off and the intermittent
durations of the malfunction will also be erased automatical-
ly. In this case, the erasure is not included in the number
of times erased.
NOTE
If the A/D converter inside the SRS diagnostic unit is mal-
functioning, diagnostic codes No. 41, 42 and 43 will not
be erased by the automatic diagnostic code erasure func-
tion. Furthermore, during cranking, none of the codes will
be erased by this function.