Compressor; High Pressure Relief Valve - Mitsubishi Eclipse Technical Information Manual

Hide thumbs Also See for Eclipse:
Table of Contents

Advertisement

C O M P R E S S O R
The A/C system on the non-turbo models incor-
l
porates a belt locking control function which
prevents the belts from being broken due to
a slip that would occur when the compressor
is locked. This function is achieved by the belt
lock controller located below the blower motor.
The controller compares the compressor speed
obtained from the compressor revolution pick-up
sensor with the engine speed and stops the
Blinking A/C switch

Compressor

side
1 0 0
EQUIPMENT - Heater and Air Conditioning

HIGH PRESSURE RELIEF VALVE

The valve, which is normally closed by the spring force, is
forced open to release the refrigerant into open air when the
high-pressure side pressure becomes so high that it overcomes
the spring force. When the pressure is lowered back to the
normal level, the valve is closed by the spring force not to
let out any more refrigerant.
Fully open
A/C if the result of the calculation exceeds the
predetermined value.
When the compressor is locked, the compressor
operation indicator light in the A/C switch blinks
to warn the driver of the abnormal condition.
A high pressure relief valve is provided to limit
the release of the refrigerant into air to a mini-
mum when the high-pressure side pressure be-
comes too high.
High pressure
relief valve
High pressure
relief valve