Service Valve - Mitsubishi Eclipse Technical Information Manual

Hide thumbs Also See for Eclipse:
Table of Contents

Advertisement

Section
Meltable
bolt
(Abolished)
New refrigerant
Conventional
refrigerant
system
system
Charging hose
EQUIPMENT - Heater and Air Conditioning
C O N D E N S E R F A N A N D R A D I A T O R F A N C O N -
T R O L
For information on condenser fan and radiator fan control,
refer to Group 1 Control System of Engine.
RECEIVER
A-A
The new refrigerant (R134a) is highly hygroscopic and
l
would require much more amount of conventional desiccant
(silica gel) to be kept dry.
iccan
The new desiccant (molecular sieve) used for drying the
refrigerant has enough capacity to absorb moisture without
need for change to the receiver capacity.
In the conventional design, the meltable bolt on the receiver
l
fuses to let out the refrigerant gas in its entirety into open
air when the high-pressure side pressure becomes too
2 0 x 0 1 9 7
high.
The new system has a relief valve in the compressor which
plays the same role as the meltable bolt but closes after
release of only necessary quantity of refrigerant, so that
the amount of released refrigerant is limited to the minimum.
NOTE
For details about the relief valve, see COMPRESSOR,

SERVICE VALVE

A quick-disconnect type joint, instead of conventional screw-in
type joint, is used for the service valve to prevent incorrect
charging and enhance serviceability.