Software Requirements - NCR RealPOS 70XRT User Manual

Hide thumbs Also See for RealPOS 70XRT:
Table of Contents

Advertisement

10-2 Chapter 10: Wedge to USB MSR Software Migration

Software Requirements

The software that supports the USB MSR is available in the Retail Platform Software for 
Windows (RPSW), version 1.3.0 (or later). 
Setting up the software to support the USB MSR requires two components. The first is 
to have the OPOS Service Object and supporting DLL installed on the system, and the 
second is to have the OPOS Profile configured properly to use this software. 
1. OPOS Service Object and Supporting DLL 
2. The OPOS Profile must have the following properly configured: 
RPSW versions 1.5.2 (and above) installs the correct DLLs onto the system when 
default installation options are chosen, but they do not create a default profile that 
uses the MSR. RSPW versions 3.0.1.0 (and later) does create a default profile 
(NCRMSR.2) that uses the NCRFitClient.MSR. However, the MSR Interface is set to 
Integrated. Changing this to USB creates a profile that works with the 7403 USB MSR. 
For RPSW versions before 1.5.2 the DLLs required to use the USB MSR are not 
installed by default configuration selections. In order to use these versions with the 
USB MSR a modified installation must be performed. The NCR5932 Service Object 
feature must be added when performing the installation. A default profile 
(NCRMSR.3) is created and properly configured during installation to use the USB 
MSR. 
On your current Wedge MSR you are most likely using either the default OPOS 
Wedge profile (NCRMSR.1) or a profile with a name of your choice, which is 
configured the same as the default profile. If you want to keep the same profile name 
you must replace the existing Wedge configured profile with a profile by the same 
name configured to use the USB MSR. Below is the default NCRMSR.3 profile 
showing the proper configuration options for using the USB MSR. 
[HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ServiceOPOS\MSR\NCRMSR.3]
@="NCRFitClient.MSR"
"Description"="NCR 74XX MSR Service Object"
"MSR"="USB"
"NCRVersion"="2.4.1.0 -> NCR Release File Version"
"ProductID"="0 -> ProductID: Maximum 0xFFFF hex"
"TimeOut"="800"
"Type"="ISO"
"VendorID"="0 -> VendorID: Maximum 0xFFFF hex"
"Version"="1.3.0"
Service Object: NCRMSR.DLL 
Supporting file: NCRHID_DLL.DLL 
Programmatic ID: NCRFitClient.MSR  
MSR Interface: USB 