The power supply plug must be accessible after installation. WARNINGS Do not close or reduce the dimensions of the airing vents in the place of installation. The airing vents are indispensable for Installation must be carried out by qualified staff and/or correct combustion.
Heat generator which opening is only allowed through the loading SAFETY DEVICES of the fuel during use. BIOMASS SAFETY DEVICES Biological material, excluding the material incorporated in Key: * = present, geological formations and transformed into fossils. - = not present BIOFUEL Fuel produced directly or indirectly by biomass.
appliance towards the installation room. Insulating product The installation must be preceded by checking the chimneys, fl ues or unload terminals positioning regarding: Installation prohibitions < 45° Legal distances Limitations disposed by local administrative regulations or particular authority prescriptions. Conventional limitations deriving from condominium regulations, constraints or contracts.
4.3.2. CHIMNEY OR INDIVIDUAL FLUE The chimney or individual fl ue must respond to the following requisites: seal the combustion products, be waterproof and adequately insulated in line with the use conditions; be realised with materials which resist the normal mechanical stresses, heat, action of the fuel products and any condensing;...
layouts below. The chimney cap must not have mechanical intake means. FLAT ROOF 50 cm External pipe that is isolated 50 cm > 5 m < 5 m < 5 m fi gure 9 inspection SLOPING ROOF fi gure 7 >A <A >50 cm...
The air fl ow can also be Comfort Maxi obtained from an adjacent room, as long as the fl ow takes place freely through permanent openings communicating with the outside. The adjacent room, with respect to the installation room, must not...
Regarding the air intake box, it is possible to apply the intake pipe above the base or below depending on requirements. These operations must be carried out by a qualifi ed technician and/or the manufacturer's technical after-sales assistance. COMFORT MAXI - MINI fi gure 20 5.3. AIR CIRCULATION PIPES It is necessary to create air recirculation inside the structure that covers the insert for correct functioning.
After having evaluated the correct position, the machine body must be detached in order to fi x the sliding base: use the supplied COMFORT MAXI - P80 Allen key to turn the lockbolt clockwise (present at the front in the bottom left or right, depending on the model).
5.6. INSERT EXTRACTION 6.2. ELISIR The “Elisir” model can be ducted at the rear of the machine, laterally The extraction of the Comfort allows to load pellets inside the feed- and from above. box and to perform routine maintenance, (cleaning the ash pipe at the end of the year) or extraordinary maintenance (replacement of mechanical parts if the product should break).
PELLETS AND FEEDING The pellets used must comply with the features described by the Standard: Ö-Norm M 7135 DIN plus 51731 UNI CEN/TS 14961 Extrafl ame recommends the use of pellets with a diameter of 6mm with its products. WARNINGS!!! THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF YOUR STOVE AND CAN DETERMINE THE INVALIDITY OF THE...
PRODUCT FUNCTIONALITY 8.1. CONTROL BOARD P3P4 fi gure 39 ON/OFF BUTTON P2 P3 SETTING ROOM TEMPERATURE P4 P5 REGULATION OF FUNCTIONING POWER DISPLAY OF THE VARIOUS TEXT MESSAGES DISPLAY OF THE POWER 8.2. DISPLAY ICONS KEY It indicates functioning of the fumes motor. It indicates weekly programming functioning Off = fumes motor not working Indicator on = Weekly programming on...
FUNCTIONING CYCLE 9.3. WORK Once the machine has been ignited, the machine starts to work. Regulate the desired room temperature using the P2 and P3 9.1. BASIC INSTRUCTIONS keys. Set the functioning power (from 1 to 5) using the P4 and P5 The following recommendations must be followed the fi rst times keys.
ADDITIONAL the fl ashing LED relative to the ducting motor Two external clamps are envisioned in the Elisir and Comfort Plus THERMOSTAT models. The ducting thermostat clamp is that fi tted with jumper as N.B. : Installation must be performed by an authorised technician per standard.
SETTINGS MENU To enter the menu, press the P5 key for three seconds. FUNCTION MENU SCROLLING TEXT VALUE MON...SUN Setting the day of the week HOURS 00...24: Adjustment of the hour MINUTES :00...59 Adjustment of the minutes CLOCK 1...31 Adjustment of the day MONTH 1...12 Adjustment of the month...
At this point, press the P5 to confi rm and continue programming. SET CLOCK START PRG1 OFF scrolling text will appear. Mon, Tue, Wed, ...Sun hours 0...23 Let's set the time spans as per example: minutes 00...59 SETTING FIRST TIME SPAN SWITCH-ON TIME date 1...31 month...
SETTING THE TEMPERATURE FOR THE FIRST TIME SPAN 12.2.3. CHRONO MENU TABLE The following table gives all weekly programmer function press the P5 key, SET PROG1 parameters. will appear followed by a temperature regulate the temperature using the P2 or P3 keys, PRG1 will appear followed by the temperature set press the P5 key to pass to the second time span...
12.3. LANGUAGE The regulation to be performed is a percentage. Therefore a modifi cation of this parameter will lead to a proportional variation of all stove feeding speeds. It is possible to select the preferred language to display the various messages.
STBY FUNCTION SET AT OFF (FACTORY SETTING) 12.4.4. KEYS LOCKED The menu allows to lock the display keys (like mobile phone). If the Stby function is not active (OFF), if the stove reaches the room Controls procedure temperature set, it will go to minimum, modulating and displaying Press the P1 and P5 keys together.
CLEANING THE UTILITY Some images could be off set from the original model. DAILY fi gure 47 fi gure 48 fi gure 49 fi gure 50 Burn pot: remove the burn pot Scrapers: use the scrapers, using an upward movement (for models with upper scrapers) or pulling from the relevant compartment and pushing the same (for the inserts and models with front scrapers).
MONTHLY Cleaning the heat exchanger: the heat exchangers chamber must be cleaned every month as the soot deposited on the rear of the cast iron hearth wall blocks the regular fl ow of fumes. It is therefore recommended to remove the ash in the combustion chamber at least once a week using a suitable suction device.
TECHNICIAN YEARLY CLEANING Fumes motor Gaskets Combustion chamber (disassembly and inspections, ash drawer (total cleaning of the cleaning and fumes and door (replace them entire chamber) pipe), new silicone in and apply silicone envisioned points where envisioned) Feed box (complete Room air fan Check air intake pipe emptying and...
DISPLAYS Display Reason Solution IGNITION The ignition phase is in progress START-UP The start phase is in progress When the stove switches off , it is necessary to wait until complete COOLING STAND- A new ignition is attempted when the fumes motor switch off and then clean the burn pot.
ALARMS DISPLAY EXPLANATION SOLUTION Indicates the presence of an alarm. On: indicates the presence of an alarm Off : indicates the absence of alarms Flashing: indicates the deactivation of the depression sensor. The alarm can be reset by pressing key 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have passed from displaying the same alarm.
Installation must be performed by qualifi ed staff , under the responsibility of the person appointing him, EXTRAFLAME S.p.A. is not liable for any damage that can, directly who will assume complete responsibility for the defi nitive...
Page 32
EXTRAFLAME S.p.A. Via Dell’Artigianato, 12 36030 MONTECCHIO PRECALCINO Vicenza - ITALY Tel. 0445/865911 Fax 0445/865912 http://www.lanordica-extraflame.com E-mail: info@extraflame.com Extrafl ame si riserva di variare le caratteristiche e i dati riportati nel seguente fascicolo in qualunque momento e senza preavviso, al fi ne di migliorare i propri prodotti.