Electronic Gas Valve Wiring Instructions; Electrical Box Connection - Majestic 33BDVT Installation Instructions & Homeowner's Manual

Builder top vent direct vent models
Table of Contents

Advertisement

Vermont Castings, Majestic Products.
EB-1 E
LECTRICAL
The replace, when installed, must be electri-
cally connected and grounded in accordance
with local codes or, in the absence of local
codes, with the current CSA C22.1 Canadian
Electric Code.
For U.S.A. installations follow the local codes
and the national electrical code ANSI/NFPA No
70.
It is strongly recommended that the wiring of
the EB-1 Electrical Junction Box be carried out
be a licensed electrician.
Ensure that the power to the supply line has
been disconnected before commencing this pro-
cedure.
The EB-1 Electrical junction box has been tted standard on
this model to allow for the easy connection of an optional
fan kit.
To connect the EB-1 box to the house electrical supply follow
the steps below.
1.
Unscrew the retaining screw from the EB-1 base plate,
Fig. 8 and remove the EB-1 assembly from the appliance.
2.
Remove the front cover of the EB-1 box.
3.
Remove the plug socket assembly from the EB-1 box.
4.
Feed the supply line in through the EB-1 opening in the
side of the appliance and then through the back of the
EB-1 assembly, Fig 8.
5.
Connect the black wire of the power supply line to the
brass screw (polarized) of the socket assembly.
6.
Connect the white wire of the power line to the chrome
screw of the socket assembly.
7.
Connect the ground wire of the supply line to the green
screw of the socket assembly.
8.
Ret the socket assembly back into the electrical box and
replace the cover plate. Secure the cable with the clamp
on the outside of the EB-1 base plate and ret the EB-1
assembly to the unit with the screw removed in step 1.
INSIDE
OUTSIDE
33/36/39/43 BDVT
B
OX
EB-1 assembly
Retaining
screw
Fig. 8
E
LECTRONIC
This appliance may be tted with either a Synetek ignition
module or a Honeywell ignition module. The method of
operation is the same in both cases, however the wiring
layout is different therefore it is important to correctly iden-
tify the unit and follow the correct wiring diagram.
Installation the remote electronic starter switch
1. Thread the wiring through the holes on the side panels of
the appliance. Take care not to cut the wire or insulation
on metal edges. Route the wire to a conveniently located
receptacle box.
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the other ends of the wire to the gas control valve
as shown in Fig. 9 or 10.
MV
1 2 3 4
RED
ORANGE
POWER CORD
120 VAC RTN
BLACK
BLACK
120 VAC HOT
GREEN
40VA TRANSFORMER
Honeywell Ignition Module
-8-
G
C
AS
ONTROL
PILOT
HONEYWELL IGNITION MODULE
24V
MV/VP
PV
GND
GND
24V
SENSE
SPARK
5 6
8
9
GREEN
LO
HI
NOVA SIT 822 VALVE
BLUE
WHITE
24 VAC HOT
BLACK
BLACK
OFF
YELLOW
BLACK
WHITE
24 VAC RET
10002555/0
V
ALVE
WALL SWITCH
Fig. 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

36bdvt39bdvt43bdvt

Table of Contents