C
B
Adjustable Drywall Strip
F
INAL
Non-combustible materials such as brick or tile may be
extended over the edges of the face of the appliance. DO NOT
cover any vent or grille panels.
If a Trim Kit is going to be installed on the replace, the brick
or tile will have to be installed ush with the edges of the
appliance.
33/36/39/43 BDVT
A
A = 1/2" (13 mm) Drywall
B = 5/8" (16 mm) Drywall
C = 3/4" (19 mm) Drywall
Fig. 3
Adjustable 13mm, 16 mm
& 19 mm spacing
Fig. 4
F
INISHING
33BDVT / 36BDVT / 39BDVT / 43BDVT
CERTIFIED TO
ANSI Z21.88b-1999 / CSA Z2.33b-M99
Vented Gas Fireplace Heaters
G
AS
Model
Fuel
33BDVTRN
Nat.
33BDVTRP Prop.
33BDVTEN
Nat.
33BDVTEP Prop.
36BDVTRN
Nat.
36BDVTRP Prop.
36BDVTEN
Nat.
36BDVTEP Prop.
39BDVTRN
Nat.
39BDVTRP Prop.
39BDVTEN
Nat.
39BDVTEP
Prop.
43BDVTRN
Nat.
43BDVTRP Prop.
43BDVTEN
Nat.
43BDVTEP
Prop.
G
I
AS
NLET
Input Minimum
Input Maximum
Manifold Pressure
-6-
S
PECIFICATIONS
Max.
Input
Gas Control
BTU/h BTU/h
Millivolt
15,000 10,500
Millivolt
15,000 11,250
24V Hi/Lo
15,000 10,500
24V Hi/Lo
15,000 11,250
Millivolt
18,000 12,600
Millivolt
18,000 13,500
24V Hi/Lo
18,000 12,600
24V Hi/Lo
18,000 13,500
Millivolt
22,000 15,400
Millivolt
22,000 16,500
24V Hi/Lo
22,000 15,400
24V Hi/Lo
22,000 16,500
Millivolt
25,000 17,500
Millivolt
25,000 18,750
24V Hi/Lo
25,000 17,500
24V Hi/Lo
25,000 18,750
& M
ANIFOLD
P
RESSURES
LP (Propane)
Natural Gas
4.5" WC
11" WC
7" WC
13" WC
3.5" WC
10" WC
10002555/0