Vermont Castings, Majestic Products.
e) Mount the conversion label supplied with the conver-
sion screw to the valve in a visible position.
10. Reassemble the replace in the reverse order, except for
the front glass. Leave this off until the unit has been
checked for leaks and the gas supply line has been bled.
11. After bleeding the gas line and checking for leaks with a
soap solution, replace the front glass. Fire up the unit,
check for ame impingement on the logs, adjusting them
if necessary. Check the manifold and supply pressures
against the appliance specications.
The procedure for converting from one gas to
another is the same regardless of the initial gas
used. The only variation is in the orice sizes
and component part numbers. Your authorized
service provider will ensure the correct parts are
used.
Nova SIT820 Gas Valve
33/36/39/43 BDVT
Honeywell Gas Valve
Fig. 11
-10-
Regulator Cap
Conversion Screw
Pressure
Regulator
Housing
Fig.12
10002555/0