Contact Id Page; Telephone Numbers To Call; Events Description; Contact Id Default - DSC GS3055-IG User Manual

Gs3055-i series gsm/gprs alarm communicator
Table of Contents

Advertisement

Available languages

Available languages

Contact ID Page

This page will allow you to set up the Contact ID function.

Telephone numbers to call

Four telephone numbers of up to 20 digits (digits and + signs).
This Device will try each telephone number 3 times before considering a call unsuccessful and quitting.
, , , , , The Contact ID Codes will be sent to the first number (with Contact ID reporting protocol) that answers the call.

Events description

z Customer Code - type in a 4 character code (accepted values: digits and the letters A, B, C, D, E and F).
To send the SMS it is necessary enter a Customer Code (e.g. 1111) for the relevant event.
z Event Code - type in the Contact ID to be transmitted when the respective event occurs.
z Send - select (tick) the events to be sent.

Contact ID default

Click on this button to assign the following Event Codes to the events manage by this Device.
Event Description
Input 1 activation
Input 1 Restoral:
Input 2 activation:
Input 2 Restoral:
Input 3 activation:
Input 3 Restoral:
Input 4 activation:
Input 4 Restoral:
PSTN Line down:
PSTN Line Restoral:
12V INPUT LOSS:
12V INPUT RESTORAL:
LOW BATTERY ALERT:
LOW BATTERY RESTORAL:
PERIODIC REPORT:
GSM UNIT ACTIVATION:
GSM INTERNAL BUFFER FULL:
FTC EVENT:
FTC RESTORAL:

Send over GPRS

If this option is enabled, this Device will only communicate Contact ID events via the GPRS network.

Periodic Reports

This Device can be programmed to send Periodic Contact ID reports. This section will allow you to select the Date and Time of the first
periodic report and the Interval between reports.
If the external power supply (connected to terminals [+12V]) and battery power supply drop at the same time, the Device
must be re-programmed after the power supply is restored, otherwise the time set for the Periodic Report could NOT be
respected.
Event Code
E
110
R
110
E
120
R
120
E
130
R
130
E
150
R
150
E
351
R
351
E
337
R
337
E
338
R
338
E
603
R
552
E
624
E
354
R
354
Sur-Gard System III / II Description
FIRE ZONE 001
FIRE ZONE 001
Panic Alarm ZONE 002
Panic Alarm ZONE 002
Burglary ZONE 003
Burglary ZONE 003
24 HOUR (AUXILIARY) ZONE 004
24 HOUR (AUXILIARY) ZONE 004
TELCO 1 FAULT 000
TELCO 1 FAULT 000
EXP. MOD. DC LOSS 000
EXP. MOD. DC LOSS 000
EXP. MOD. LOW BAT 000
EXP. MOD. LOW BAT 000
Periodic RF Xmission 000
Radio Xmitter Disabled 000
EVENT LOG OVERFLOW 000
FAILURE TO COMMUNICATE 000
FAILURE TO COMMUNICATE 000
G
13

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Gs3055-igw

Table of Contents