Part Set Groups
This option allows the engineer to define how
the three part set buttons operate. Each group
can be programmed so that it sets any
combination of wards. For example "PART SET
GROUP A" could be allocated wards A and C,
whereas "PART SET GROUP B" could be allocated
wards A and B.
Each "Part Set Group" can also have up to 32
characters of text assigned, see "Part Set Text"
on page 48.

Part Set Group Operation

When a "Master" or "Standard" user passcode is
entered during the unset mode the system will
attempt to fully set after a five second delay.
However, if during the five second delay one of
the part set buttons [A], [B] or [C] is pressed, the
display will show relevant "Part Set Text" and
after a short delay the system will set the wards
that are assigned to the selected "Part Set
Group".
Part Set Groups Flowchart
[3.2]
Code Set Groups
This option allows the engineer to define how
the four code set groups operate. Each group
can be programmed so that it sets any
combination of wards. For example "CODE SET
GROUP A" could be allocated wards A and C,
whereas "CODE SET GROUP B" could be
allocated wards A and B.

Code Set Group Operation

When the system is unset and a "Code Set
Group" passcode is entered the selected wards
will set after the setting procedure is followed.
e.g., If "Code Set Group A" is defined as above
then when the passcode is entered it will set
wards A and C. If the system is fully set and the
passcode is entered it will unset wards A and C.
The "Code set Group" passcodes are
programmed by the master user within "User
menu 2" (see User Manual).