Installation Instructions

GENERAL

Condensers must be mounted horizontally with the fan
motor on top with nothing obstructing it. There must be
at least a 16" clearance from the bottom for air intake.
The front coupling panel & one other panel (back or
side) must also be unobstructed.
Remote condenser installations consist of vertical and
horizontal line sets between the ice machine and the
condenser. When combined, they must fit within
approved specifications. The following guidelines,
drawings and calculation methods must be followed to
verify a proper remote condenser installation.
2
SV1204
2-18
3
1
Routing Line Sets
! Caution
The 60 month compressor warranty (including the
36 month labor replacement warranty) will not apply
if the remote ice machine is not installed according
to specifications.
This warranty also will not apply if the refrigeration
system is modified with a condenser, heat reclaim
device,
or
other
parts
manufactured by Manitowoc Ice unless specifically
approved in writing by Manitoc Ice.
DOWNWARD
HORIZONTAL
SPIRAL
1
Section 2
or
assemblies
2
3
Part Number 000000966 03/09