Installation Check List; Additional Checks For Remote Models - Manitowoc S Installation, Use & Care Manual

S model
Hide thumbs Also See for S:
Table of Contents

Advertisement

Section 2

INSTALLATION CHECK LIST

Is the Ice Machine level?
Has all of the internal packing been
removed?
Have all of the electrical and water
connections been made?
Has the supply voltage been tested and
checked against the rating on the nameplate?
Is there proper clearance around the ice
machine for air circulation?
Is the ice machine grounded and polarity
correct?
Has the ice machine been installed where
ambient temperatures will remain in the
range of 35° - 110°F (1.6° - 43.3°C)?
Has the ice machine been installed where the
incoming water temperature will remain in the
range of 35° - 90°F (1.6° - 32.2°C)?
Is there a separate drain for the water-cooled
condenser?
Is there a separate drain for the bin?
Are the ice machine and bin drains vented?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed
regarding maintenance and the use of
Manitowoc Cleaner and Sanitizer?
Part Number 000000966 03/09
Has the owner/operator completed the
warranty registration card?
Has the ice machine and bin been sanitized?
Is the toggle switch set to ice? (The toggle
switch is located directly behind the front
panel).
Is the ice thickness control set correctly?
(Refer to Operational Checks to check/set
the correct ice bridge thickness).
S3300 Only - Is the compressor direction of
rotation correct? The ice machine will have
high suction pressure, low discharge
pressure and will be noticeably loud.
Reverse any two incoming power leads to
reverse rotation.

ADDITIONAL CHECKS FOR REMOTE MODELS

Has the receiver service valve been
opened?
Does the remote condenser fan operate
properly after start-up?
Has the remote condenser been located
where ambient temperatures will remain in
the range of -20° - 120°F ( -29 - 49°C).
Is the line set routed properly?
Are both refrigeration lines to remote
condenser run so they do not lay in water
and are properly insulated?
Installation Instructions
2-23

Hide quick links:

Advertisement

Table of Contents
loading