Safety

If a safety mechanism has been activated in the system a safety code will be shown in the display for the
temperature in the indoor unit.
Sequence
Fault
1
Hot gas temperature too high
2
Gas temperature too high indoors in heating mode
3
Temperature too high on defrost sensor in cooling mode
4
Voltage too high
5
Current too high
6
Not used
7
Overheating of control
8
Overheating of IPM
9
Run mode protection

TECHNICAL DATA

Anslut 417030
Refrigerant
COP
For homes up to*
Heat output max.
Cooling capacity max.
Power consumption comp. system -
heating
Power consumption comp. system -
cooling
Nominal heat output
Operating range
Dehumidifying capacity in c oling
mode
Maximum air flow from indoor unit
10°C minimum heating function
Night-reduction function
Automatic defrosting
Heating cable for defrosting
Preheating of compresso
Electronic expansion valve
Restart after power failure
Compressor
Noise level, indoor unit
Noise level, outdoor unit
Weight of indoor unit
Weight of outdoor unit
Dimensions of indoor unit w x h x d
Dimensions of outdoor unit w x h x d
Installation kit 4 metres included
Supply voltage, earthed**
Residual current device and surge
protection
* This figure is an estimate and depends on insulation and climate in home.
** Delay action fuse
ENGLISH
R410A
4,5
160 m²*
5300 W
4100 W
410 - 1600 W
370 - 1800 W
4900 Watts
-20℃ - +40℃
1.7 l/h
650 m³/h
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Panasonic Inverter Rotary
38 dB
47 dB
10 kg
33 kg
915 x 185 x 290 mm
780 x 255 x 590 mm
Yes, with quick-coupling
230 Volt, 50 Hz, 10 A
Required
114
Error code
P1
P7
P8
P3
P4
-
P6
P2
P9