4.1.6 Temperature / Time Predetermined Level Transducer
The temperature needed or the desired time are set by means of this component,
according to the function set at the RHEA User Interface. These parameters can be
changed from the basic position, by a 30° turn to the right and holding the turning grip in
this positive position (increasing) or by a 30° turn to the left and holding the turning grip
in this negative position (decreasing). If the predetermined level transducer is released
after the level needed and wished has been reached, it will spring back to the initial
position. The signals received will be accepted and processed by the RHEA User Inter-
face.
4.1.7 Door switch for the light
When opening the door of the oven, the lighting of the oven is activated over this component after
the device has been switched on. The mounting position is at the top and right-hand corner of the
front frame of the oven
DGS-TDS-N 05.09 A. B. © Electrolux
Switch axis
Electrical terminals
- 25 -
599 518 252
EN