5.

Technical equipment

5.1

Temperature safety device

With built-in appliances, there is a temperature fuse on the side of the air channel that switches off
the appliance in the event of overheating. The measured temperature value during a cutoff is 90°C.
Fig.: Built-in position - Temperature fuse
Notes:
-
-
5.2

Fan after-running

The cooling fan switches on automatically when putting the appliance into operation. First it is in
operation to keep cool the appliance surfaces. After the oven was switched off, the fan continues
running to cool the appliance and then switches off automatically at a centre of gravity temperature
of the muffle of approx. 120°C-130°C. The post-operative ventilation is controlled via the
electronics.
Note:
-
-
5.3

Measure against wrong electrical connection

Not provided.
DGS-TDS-N 05.09 A. B. © Electrolux
for wiring diagram see chapter 7
Deviations possible with floor-mounted stoves
for wiring diagram see chapter 7