Specifications - Empire Comfort Systems DVP42 Series Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Input Btu/hr Maximum
Btu/hr Minimum (millivolt only)
KWH (Maximum)
(Minimum)
NAT.
Orifice
Air Shutter Opening
LP
Orifice
Air Shutter Opening
Height without standoff
Width
Depth
Gas Inlet Shutoff Valve (Pipe)
NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
31455-4-1113

SPECIFICATIONS

#38 (.1015) P-203 - (DVP42FP(3,7,9))
3.25 mm P-306 - (DVP42FP5)
#52 (.0635") P-185
Remote Control Options
& Accessories
FRBC
FRBTC
TMW
TRW
FWS-1
FREC
FBB4
DVP42
28,000 (Nat)
28,000 (LP)
19,000 (Nat)
22,000 (LP)
8.2
5.5
1/8"(3.2mm)
FULL OPEN
34 3/4"(883mm)
43"(1092mm)
19 7/8"(505mm)
1/2 NPT
Description
Millivolt/IP Battery Remote ON/OFF
Millivolt/IP Battery Remote T-Stat
Millivolt/IP WIRELESS Wall Thermostat
Millivolt/IP REED SWITCH Wall Thermostat
Direct Ignition/Millivolt/IP Wall Switch
Electric Remote
Blower Assembly
DVP48
30,000 (Nat)
30,000 (LP)
20,500 (Nat)
24,000 (LP)
8.8
6.0
#37 (.1040) P-213 - (DVP48FP(3,7,9))
#34 P-270 - (DVP48FP5)
1/8"(3.2mm)
1.65MM P-250
FULL OPEN
34 3/4"(883mm)
49"(1245mm)
19 7/8"(505mm)
1/2 NPT