Empire Comfort Systems DVP42 Series Installation Instructions And Owner's Manual page 16

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

REAR ONLY, STRAIGHT OUT THE BACK
"A"
6"(152mm)
5 1/8"(130mm) to 6 /2"(165mm)
9"(229mm)
8 1/8"(206mm) to 91/2"(241mm)
12"(305mm) 11 1/8"(283mm) to 12 1/2"
(317mm)
TOP, 90° ELBOW TO HORIZONTAL OUT THE WALL
"A"
6"(152mm)
11 1/4"(286mm) to
12 3/4"(324mm)
9"(229mm)
14 1/4"(362mm) to
15 3/4"(400mm)
12"(305mm)
17 1/4"(438mm) to
18 3/4"(476mm)
Page 16
INSTALLATION
"B"
MODEL
DVP 42,48
DVP 42
DVP 42
Figure 18
"B"
"C"
4 3/4"(121mm) to
6 1/4"(159mm)
7 3/4"(197mm) to
9 1/4"(235MM)
10 3/4"(273mm) to
12 1/4"(311mm)
Figure 19
CORNER INSTALLATION TOP, 90° ELBOW TO HORIZONTAL
OUT THE WALL
Dim.
DVP42
45 3/8"
A
1152mm
32 1/8"
B
816mm
13 3/8"
C
34 mm
64 1/8"
D
1628mm
Figure 20
CORNER INSTALLATION REAR, 45° ELBOW
TO HORIZONTAL OUT THE WALL
DVP42
"A"
6"(152mm)
4"(102mm) to
5 1/2"(140mm)
9"(229mm)
6"(152mm) to
7 /2"(191mm)
12"(305mm) 9"(229mm) to
10 1/2"(267mm)
Figure 21
DVP48
49 5/8"
1260mm
35 1/8"
892mm
15 1/2"
39 mm
70 1/8"
1781mm
DVP48
"B"
"B"
4"(102mm) to
5"(127mm)
6"(152mm) to
7 1/2"(191mm)
9"(229mm) to
10 1/2"(267mm)
31455-4-1113