Converting flue take-off to rear venting
When switching out the flue and inlet vent collars to run horizontally
off the rear vent, the following steps must be taken.
1.
Remove the inlet vent collar (8 screws) and flue collar (4 screws)
from the top of the fireplace, and set to the side.
2.
Remove the inlet cover plate and flue cover plate located on
the back of the fireplace. These will be used to close the top
flue and inlet openings.
3.
Insert the insulation retainer bracket and insulation into the top
flue pipe before reinstalling the flue cover plate over the top
flue with 4 screws.
Page 24

REAR VENT CONVERSION

Figure 40
4.
Reinstall the inlet cover plate over the top inlet opening with 4
screws. See illustration above.
5.
Install the flue collar assembly to the rear flue with 4 screws.
6.
Install the inlet vent collar to the rear of the fireplace with 8
screws.
7.
This completes the conversion for a rear vent application.
WARNING: For top vented installations, the insulation and
retainer are to be removed from the flue pipe and discarded.