Fixture Linking; Data Cabling - SHOWTEC Indigo 150 LED User Manual

Hide thumbs Also See for Indigo 150 LED:
Table of Contents

Advertisement

4. Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
5. Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the
other end of the mains power cord into proper electric power supply sockets, starting with the first unit.
Do not supply power before the whole system is set up and connected properly.
Note : Link all cables before connecting electric power

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures the
data link can support.
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically
isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of Indigo„s on a DMX data link: 30 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
DAP Audio Certified DMX Data Cables
• DAP Audio cable for allround use.
Ordercode FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.).
• DAP Audio cable
Neutrik®. Ordercode FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.).
Multiple Indigo's DMX Set Up
bal. XLR/M 3 p. > XLR/F 3 p.
for the demanding user with exceptional audio-qualities and connector made by
9
Fig. 4

Hide quick links:

Advertisement

Table of Contents
loading