Whisper Power M-SQ25 Installation Manual page 6

1500 rpm marine diesel generating set 230/400v / 50hz digital diesel control
Hide thumbs Also See for M-SQ25:
Table of Contents

Advertisement

INSTALLATION
5
A
Fig. 4 Fuel supply
1 Fuel return
2 Fuel supply
3 Prefilter / Water separator (optional)
4 Extra fuel lift pump (optional)
5 Fuel tank
Both supply and return fuel pipe lines should be
appropriate material and 8 mm outer diameter tubing. The
quality of the tubing of fuel pipes could be submitted to
local regulations depending on the application of the
vessel.
The fuel pipes can be plumbed to the flexible hoses which
are on the generating set and have a connection to fit to 8
mm pipe. This fuel lines fulfils CE standards and are
according to ISO 7840 A2. It is important to avoid bends in
the pipes, as they could trap air bubbles. The return pipe
should never be connected to the suction pipe or to other
consumers of diesel fuel, such as the propulsion engine
and heaters and return pipes
6
1
2
4
3
4
A fine fuel filter is installed which requires maintenance.
WhisperPower advises to install an extra fuel filter/ water
fuel separator near the fuel tank.
Before starting your generating set for the first time follow
the fuel system bleeding procedure in the users manual.
FUEL FILTERS
Oktober 2010 / M-SQ25 / EN

Advertisement

Table of Contents
loading

Table of Contents