Connect to the electricity supply
Warning: This appliance must be earthed.
The hob must be installed by a competent electrician,
using a suitable double pole control unit, with 3mm mini-
mum contact separation at all poles.
We recommend that the appliance is connected by a
qualified electrician who will comply with the I.E.E. and
local regulations.
Connection should be made with a suitable cable.
G
Strip the wires & connect to the terminal block as
G
shown in the diagram & table below.
Fit the cable clamp & secure with the torx head
G
screw provided.
Close the terminal box, ensuring that the cover is
G
engaged on the locking tabs.
Mains cable
Installation Instructions
Wire
Live
Neutral
Earth
Cable clamp
Connect to:
Colour
Brown
Terminal
2
Blue
Terminal
4
Yellow /
Green
Important: Ensure that
i
you route all mains electri-
cal cables well clear of any
adjacent
heat
such as an oven or grill.
Bridges
source,