Rs-232C Interface Specifications; 1 ] Interface Connector And Pin Assignment - Denso BHT-300B User Manual

Bar code handy terminal
Table of Contents

Advertisement

3.2 RS-232C Interface Specifications

[ 1 ] Interface Connector and Pin Assignment

The BHT has a direct-connect interface port which is connectable to the 3-pole mini stereo plug (φ2.5
mm or 0.1") and supports a subset of the RS-232C interface as shown below.
Using a direct-connect interface cable having the mini stereo plugs makes it possible to connect the BHT
to a host PC (or another BHT) directly without any routing through the CU-300.
The poles of the plug are assigned as listed below.
Signal Name
SD
RD
SG
The input/output voltage threshold for the logical valued signal is listed below.
Logical Value
0
1
The direct-connect interface port is not designed to stand frequent connecting/disconnecting. Do not
plug and unplug basically more than one time a day; otherwise, the service life of the plug will
shorten. To connect the BHT to a host PC having no IrDA port (or another BHT) frequently, use the
CU-300.
Allow the specified signals only to enter the direct-connect interface port. Entry of other signals will
result in a failure or malfunction of the BHT.
3-pole Mini Stereo Plug (ø2.5 mm or 0.1")
Function
Send data
Receive data
Signal ground
Input Voltage Threshold
(RD)
3V min.
-3V max.
122
Signal Input/Output
BHT
External device
-
Output Voltage Threshold
(SD)
5V min.
-5V max.