Grounding The Wp-501; F Igure 3: Grounding Connection Components - Kramer WP-501 User Manual

Wall plate solution for simple room control and signal switching wp-501 kramer
Table of Contents

Advertisement

4.1

Grounding the WP-501

The grounding screw is used to earth the chassis of the unit to the building ground
preventing static electricity from impacting the performance of the unit.
This section defines the grounding screw components.
Figure 3: Grounding Connec ion Components
To ground the WP-501:
1. Connect the Ring Tongue terminal to the building grounding point wire (it is
recommended to use a green-yellow AWG#18 (0.82mm
a proper hand-tool).
2. Insert the M3x6 screw through the toothed lock washers and the tongue
terminal in the order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring tongue
terminal) into the grounding screw hole and tighten the screw.
6
#
Component Description
1
M3X6 screw
2
1/8" Toothed Lock Washer
3
M3 Ring Tongue Terminal
2
) wire, crimped with