Set The Wp-501; F Igure 4: The Setup Internal Panel - Kramer WP-501 User Manual

Wall plate solution for simple room control and signal switching wp-501 kramer
Table of Contents

Advertisement

5.1

Set the WP-501

Before installing the front panel and mounting it on the wall, you need to setup the
WP-501. This section defines the relevant internal panel components, viewed from
the front panel side:
Normal
Figure 4: The Setup Internal Panel
Feature
Program Switch
USB port for configuration
Mic Mode Switch
Factory Reset Button
8
Program Switch
Program
Factory Reset Button
Function
For firmware upgrade
Use the USB port to configure the unit (for system integrator)
Set the microphone mode switch to dynamic or condenser (by
default, this switch is set to dynamic).
It is recommended to set the mic mode switch before mounting the
WP-501 front panel (see
Disconnect the power and then connect it while pressing the
Factory Reset button (using a small screwdriver). The unit will
power up and load its memory with the factory default definitions
IP Address:
Mask:
Gateway:
USB for Configuration
Mic Mode Switch
Dynamic
Section 5.2.1
192.168.1.39
255.255.0.0
0.0.0.0
!
This operation should be carried out by
authorized Kramer technical personnel or by an
external system integrator, and requires
removal of the device from the wall by
unscrewing the four wall mount screws
Condenser
)
WP-501 - Using Your WP-501