LOCAL CODES continued
Install and use heater with care. Follow all local
codes. In the absence of local codes, use
latest edition of National Fuel Gas code ANSI
Z223.1, also known as NFPA 54*.
*Available from :
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
WATER VAPOR: A BY-PRODUCT OF VENT-FREE ROOM HEATERS
Water vapor is a by-product of gas combustion. An vent-
free room heater products approximately one (1) ounce
(30ml) of water for every 1,000 BTU's (.3KW 's) of gas
input per hour.
Ven t -f r ee roo m h eaters are rec o mm end ed as
supplemental heat (a room) rather than a primary heat
source (an entire house) . In most supplemental heat
application, the water vapor does not create a problem.
In most applications, the water vapor enhances the
low humidity atmosphere experience during cold
weather.
The following steps will help insure that water vapor
does not become a problem.
1. Be sure the heater is sized properly for the application,
including ample combustion and ventilation air.
PRODUCT FEATURES
Touch Pad
ON/OFF Switch
Satety Pilot
Figure1-Vent-Free Heater
Cabinet Top
Grill Guard
Ignitor
System
Control Knob
Control System
State of Massachusetts : The installation must be
made by a licensed plumber or gas fitter in the
Commonwealth of Massachusetts.
the
Sellers of unvented propane or natural gas-fired
supplemental room heaters shall provide to each
purchaser a copy of 527 CMR30 upon sale of the
unit.
In the State of Massachusetts, unvented propane
and natural gas-fired space heaters shall be pro-
hibited in bedrooms and bathrooms.

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged, promptly inform dealer
where you bought heater.
2. If high humidity is experienced, a dehumidifier may
be used to help lower the water vapor content of the air.
3. Do not use vent-free room heater as the primary
heat source.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Fresh
Air for Combustion and Ventilation, pages 5 and 6.