Power Requirements
The following tables represent the PSU's capabilities and do not represent the S6000's operation.
AC Input Specification
Parameter
Power supply
Maximum current draw per system
Maximum power consumption
Reliability
DC Input Specification.
min/max input voltage range
input power at full load
input current at full load
Start up VDC
Start off VDC
IEEE Standards
The S6000 system complies with the following IEEE standards:
• 802.1AB LLDP
• 802.1ag Connectivity fault Management
• 802.1D Bridging, STP
• 802.1p L2 Prioritization
• 802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
• 802.1s MSTP
• 802.1w RSTP
• 802.3ab Gigabit Ethernet (1000BASE-T)
• 802.3ac Frame Extensions for VLAN Tagging
• 802.3ad Link Aggregation with LACP
• 802.3ae 10 Gigabit Ethernet (10GBASE-X)
44
|
Specifications
Specifications
100–240 VAC 50/60 Hz
2.9 A @ 280 watts/100vac
1.4 A @ 280 watts/200vac
286 Watts
MTBF 355,178 hours
−
−
−
40.5V /
48V/
60V
−
−
40.5V/970W
48V/930W
950W (without fan)
−
−
40.5V/980W
48V/940W
960W (with fan)
−
−
40.5V/23.8A
48V/19.0A
15.6A (without fan)
−
−
−
40.5V/24A
48V/19.2A
16.0A (with fan)
−
39.0+/
1.5V
−
37.5+/
1.5V
−
60V/
−
60V/
−
60V/
60V/